top of page

Pacto & PactoPlus -Zero loss Drain valves 

zero loss drain valve feature
Silent
zero loss drain valve feature
Ample Saving 
zero loss drain valve feature
Remote Monitoring 

Pacto Zero Loss Drain Valves

Pacto Operating Principle

Condensate starts filling inside the drain valve. Air locked inside the drain valve is released through Breathe-out port. As the condensate level raises up, the Magnetic float (1) moves up and triggers the reed switch. Controller (2) receives the signal from reed switch and energize the Solenoid valve (3) for a short duration. Thus, collected condensate is drained out. Solid particles are retained over the surface of Strainer (4).

Zero loss drain valve - pacto
Pacto zero loss drain valve flow diagram

Pacto Key Feature 

1. Stainless steel float switch

Highly reliable. Reed switch housing is made of Stainless steelfor smooth and nonstick operation.

2 . E-Coated

E-Coated die cast Aluminum offers excellent corrosion protection against harsh environment.

3 . Strainer

E-Coated die cast Aluminum offers excellent corrosion protection against harsh environment.

4 . Magnetic test switch

Magnetically energized test switch offers reliable test function
even in highly humid environment

Pacto zero loss drain valve
Pacto zero loss drain valve

5 . 2 Mode of operation

Zero loss mode
Timer mode

Smart Shift Technology

The Pacto shifts its operating mode from Level sensing to Timer mode when the collected dirt is not removed from the system during periodic maintenance, thus ensuring safe operation even at extreme condition. Eventually the system comes back to level sensing drain mode once the dirt is removed. As an additional safety, a Magnetic test switch is provided to verify the drain function at any time.

Pactoplus Zero Loss Drain Valves

Pactoplus Operating Principle

Condensate starts filling inside the drain valve. Air locked inside the drain valve is released through Breathe-out port..
As the condensate level raises up, the Magnetic float (1) moves up, and provides 'Ready' signal to controller.
Once the condensate level crosses the Magnetic float (2), it triggers Controller (6) and energize Discharge valve (5), thus discharge of condensate takes place. Once the condensate level comes below the Magnetic float (1), it then denergize the Discharge valve (5) and stops the discharge. Thus, only condensate is discharged and compressed air is preserved.

Pacto zero loss drain valve
Pacto zero loss drain valve flow

Pactoplus Key Feature 

1. Smart controller - Truly intelligent

Enabled with BMS connectivity
3 Point Sensing
Intelligent detection of dirt pile up and changes its operation mode.

2. Stainless steel float switch

Float switch is completely made of Stainless steel suitable to perform even in harsh chemical environment.

3. Operating modes

Two Operating and One Alarm sensor for multi-mode operation.

4. E-Coated

Anodized die cast Aluminum offers excellent corrosion protection against harsh environment.

5. Sight Glass

Sight glass helps to ascertain proper functioning of drain valve.

6. Magnetic test switch

Magnetically energized test switch offers reliable test function even in highly humid environment

Pacto zero loss drain valve
Pacto zero loss drain valve

Smart Shift Technology

After triggering maintenance alert for remote monitoring Pactoplus shifts its operating mode from Level sensing to Timer mode when the collected dirt is not removed from the system during periodic maintenance, thus ensuring safe operation even at extreme condition. Eventually the system comes back to level sensing drain mode once the dirt is removed. As an additional safety, a Magnetic test switch is provided to verify the drain function at any time.

bottom of page