top of page

Refrigerated Air Dryer

refrigerated-air-dryer

Summits manufacture World Class Refrigerated Air Dryers with most advanced technology and reliability to ensure trouble free performance for ages.

Refrigerated Air Dryer functions on the principle of cooling the air, condensing the moisture and removing it.

Summits Refrigerated Air Dryers remove the moisture to a level of 600 ppm(w) by using energy efficient refrigeration system and effective heat exchangers. The wet air enters into the economizer (pre cooler) of the refrigerated air dryer and the temperature gets reduced significantly by the outgoing cold air. This medium temperature air further enters in to the evaporator of the refrigerated air dryer and the temperature drops to 2 Deg.C by the cold refrigerant. At this temperature the moisture in the vapour form condenses into liquid and the same is separated by high efficient integral moisture separator and automatic drain trap. All the three components (i.e. pre cooler, evaporator and moisture separator) are integrated into one single unit.

Elix - Refrigerated Air Dryers

Heat Exchanger of Summits Refrigerated Air Dryer


Summits refrigerated Air Dryers are fitted with 3-in-1 integrated high-efficiency microchannel heat exchanger with optimized construction designed with ANSYS CFD. Generously sized Air to Air heat exchanger reduces the load to the evaporator section to 1/3 of total load hence less power consumption. The stainless steel demister pad packed inside the heat exchanger efficiently removes the condensed moisture at all varying airflow.

Summits-air-dryer
Refrigeration air dryer capacity
Refrigeration air dryer work pressure

Capacity

10cfm to 15000cfm

Working Pressure
1 bar(g) to 250 bar(g)

eSave controller features of Summits Refrigerated Air Dryer

Refrigeration air dryer

Energy saving control algorithm incorporated

Refrigerated air dryer

High and Low dew point alarm can be set

Refrigeration air dryer

Service interval indication

Refrigeration air dryer

Password protected settings

Refrigeration air dryer

RS 485 communication

Refrigeration air dryer

Can be programmed to user requirement

Refrigeration air dryer

Energy saved & Money gained can be accounted S. On line dew point transmitter can be connected

Schematic Diagram

Refrigeration air dryer sematic diagram

1.    Refrigerant compressor

2.    Condenser

3.    Condenser cooling fan

4.    Liquid receiver

5.    High pressure switch

6.    Fan pressure switch

7.    Filter dryer

8.    Liquid line sight glass

9.    Solenoid valve

10.  Capillary

11.  Dew point sensor

12.  Zero air loss drain valve

13.  Moisture separator

14.  Refrigerant to air heat exchanger

15.  Air to air heat exchanger

16.  Hot gas bypass valve

17.  Accumulator

18.  Pressure transmitter

19.  Elixplus Controller prorated

Range of Elix Refrigeration air dryer

bottom of page